INSTALLATION INSTRUCTIONS
ELECTRIC DOWNDRAFT SLIDE-IN RANGES
INSTRUCTIONS D’INSTALLATION
DES CUISINIÈRES ÉLECTRIQUE À ÉVACUATION
DESCENDANTE ENCASTRABLE
Table of Contents/Table des matières
RANGE SAFETY .............................................................................2
INSTALLATION REQUIREMENTS................................................3
Tools and Parts ............................................................................3
Location Requirements................................................................3
Venting Requirements..................................................................5
Venting Methods..........................................................................5
Calculating Vent System Length..................................................6
Electrical Requirements - U.S.A. Only.........................................7
Electrical Requirements - Canada Only.......................................8
Countertop Preparation ...............................................................8
INSTALLATION INSTRUCTIONS..................................................9
Unpack Range..............................................................................9
Adjust Leveling Legs....................................................................9
Install Anti-Tip Bracket.................................................................9
Install Downdraft System...........................................................10
Electrical Connection - U.S.A. Only...........................................14
Connect Range to Downdraft System.......................................19
Complete Installation .................................................................21
Moving the Range......................................................................21
SÉCURITÉ DE LA CUISINIÈRE ...................................................23
EXIGENCES D’INSTALLATION...................................................24
Outils et pièces...........................................................................24
Exigences d’emplacement.........................................................24
Exigences concernant l’évacuation ...........................................26
Méthodes d’évacuation..............................................................27
Calcul de la longueur effective du circuit d’évacuation.............28
Spécifications électriques ..........................................................29
Préparation du plan de travail....................................................29
INSTRUCTIONS D’INSTALLATION.............................................30
Déballage de la cuisinière ..........................................................30
Réglage des pieds de nivellement .............................................30
Installation de la bride antibasculement ....................................31
Installation du circuit d’évacuation par le bas ...........................31
Raccordement de la cuisinière au circuit d’évacuation
par le bas....................................................................................35
Achever l’installation ..................................................................37
Déplacement de la cuisinière.....................................................38
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10253462A
Zobrazit stránku 0
1 2 3 4 5 6 ... 39 40

Shrnutí obsahu

Strany 1 - DESCENDANTE ENCASTRABLE

INSTALLATION INSTRUCTIONSELECTRIC DOWNDRAFT SLIDE-IN RANGESINSTRUCTIONS D’INSTALLATION DES CUISINIÈRES ÉLECTRIQUE À ÉVACUATION DESCENDANTE ENCASTRABLE

Strany 2 - RANGE SAFETY

10Wall Mounting5. Using the Phillips screwdriver, mount anti-tip bracket to the wall or floor with the two #12 x 1⁵⁄₈" screws provided.Install Do

Strany 3 - INSTALLATION REQUIREMENTS

115. Mount blower motor to the floor with 4 - #8 x ¾" hex head screws provided. 6. Go to the “Electrical Connection” section.Floor Venting1. Mark

Strany 4 - Cabinet Dimensions

126. Connect vent system to blower motor outlet (option 1 shown) with 4 - #8 x ¾" hex head screws provided.7. Go to the “Electrical Connection” s

Strany 5 - Venting Methods

137. Remove the bracket from the other side of the blower motor, rotate 180° and secure with 4 locknuts.8. Position 2 wood spacers and mount them to t

Strany 6 - Exhaust Through Window Well

14Electrical Connection - U.S.A. OnlyPower Supply Cord Direct Wire1. Disconnect power.2. Use Phillips screwdriver to remove the terminal block cover s

Strany 7 - Electrical Connection

15Style 2: Direct wire strain relief Use Phillips screwdriver to remove screws from panel on back of range. Lift range back panel up and off. Use P

Strany 8 - (for Slide-in Ranges Only)

16Electrical Connection Options4-wire connection: Power Supply CordUse this method for: New branch-circuit installations (1996 NEC) Mobile homes R

Strany 9

173-wire connection: Power Supply CordUse this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply c

Strany 10 - Install Downdraft System

183. Pull the conduit through the strain relief on cord/conduit plate on bottom of range. Allow enough slack to easily attach wiring to the terminal b

Strany 11 - Floor Venting

192. Attach terminal lugs to line 1 (black), bare (green) ground, and line 2 (red) wires. Loosen (do not remove) the set screw on the front of the ter

Strany 12 - Left or Right Side Venting

2RANGE SAFETYYou can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don'tfollow All

Strany 13

208. Check that the anti-tip bracket is installed and that electrical cords are not kinked. Use a flashlight to look underneath the bottom of the rang

Strany 14 - Power Supply Cord Direct Wire

2112. Insert downdraft vent filter and place vent cover over opening.13. Reconnect power.Complete Installation1. Check that all parts are now installe

Strany 15 - B. Strain relief

22For direct-wired ranges:1. Disconnect power.2. Disconnect range from downdraft vent system.3. Slide range forward.4. Complete cleaning or maintenanc

Strany 16 - ■ Recreational vehicles

23SÉCURITÉ DE LA CUISINIÈRERisque possible de décès ou de blessure grave si vous ne suivez pas immédiatement les instructions. Risque possible de décè

Strany 17 - (2.5 cm)

24EXIGENCES D’INSTALLATIONOutils et piècesRassembler les outils et composants nécessaires avant d’entreprendre l’installation. Lire et observer les in

Strany 18

25Autres critères à respecter pour une installation en résidence mobile : Dans le cas de l’installation de cette cuisinière dans une résidence mobile

Strany 19

26Exigences concernant l’évacuationIMPORTANT : Cette cuisinière doit être ventilée vers l’extérieur. Voir la section “Méthodes d’évacuation”. Ne pas

Strany 20

27Méthodes d’évacuationLes méthodes communes d’évacuation sont illustrées pour une cuisinière à aspiration par le bas. L’évacuation de la cuisinière à

Strany 21 - Moving the Range

28Calcul de la longueur effective du circuit d’évacuationIMPORTANT : Cette cuisinière accepte jusqu’à 60 pi (18,3 m) de conduit droit. Le mode à faibl

Strany 22 - For direct-wired ranges:

29Spécifications électriquesSi l’on utilise un conducteur distinct de liaison à la terre lorsque les codes le permettent, il est recommandé qu’un élec

Strany 23 - SÉCURITÉ DE LA CUISINIÈRE

3INSTALLATION REQUIREMENTSTools and PartsGather the required tools and parts before starting installation. Read and follow the instructions provided w

Strany 24 - EXIGENCES D’INSTALLATION

30INSTRUCTIONS D’INSTALLATIONDéballage de la cuisinière1. Ôter les matériaux d’emballage, le ruban adhésif et la pellicule protectrice de la cuisinièr

Strany 25 - Dimensions du placard

31Installation de la bride antibasculement1. Ôter la bride antibasculement fixée par du ruban adhésif à la pochette contenant la documentation.2. Déte

Strany 26

32Évacuation par le mur arrière1. Tracer sur le mur l’axe central de l’ouverture entre les placards.2. Vérifier l’absence d’obstruction avant de trace

Strany 27

33Évacuation par le plancher1. Tracer au sol l’axe central de l’ouverture entre les placards.2. Placer le gabarit sur le sol à 2¼" (5,7 cm) du mu

Strany 28 - 6 pi (1,8 m)

346. Raccorder le circuit d’évacuation à la sortie du moteur du ventilateur (option 1 illustrée) avec les 4 vis n° 8 x ¾" à tête hexagonale fourn

Strany 29 - AVERTISSEMENT

357. Dévisser le support de l’autre côté du ventilateur, le faire pivoter de 180° et le fixer avec les 4 écrous de blocage.8. Placer 2 cales en bois e

Strany 30

367. Retirer le carton ou le panneau de fibre dur de sous la cuisinière. À deux personnes ou plus, déplacer doucement la cuisinière à son emplacement

Strany 31

37 Évacuation latérale (évacuation par la gauche illustrée)Raccorder le conduit d’évacuation flexible à la cuisinière et le circuit d’évacuation à la

Strany 32 - Évacuation par le mur arrière

38Déplacement de la cuisinièreLorsqu’on déplace la cuisinière, la faire glisser sur une planche de carton ou en matériau dur pour éviter d’endommager

Strany 34

4Product Dimensions*Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.**When installed in a 24" (61 cm) base cabi

Strany 35

W10253462A© 2009.All rights reserved.Tous droits réservés.® Registered Trademark/TM Trademark of Jenn-Air, U.S.A. Used under license by Maytag Limited

Strany 36

5Venting RequirementsIMPORTANT: This range must be exhausted outdoors. See “Venting Methods” section. Do not terminate the vent system in an attic or

Strany 37 - Achever l’installation

6Left or Right Side VentingVenting Behind Cabinet Kickplate Concrete Slab Installations - Exhaust Through WallConcrete Slab Installations - Exhaust Th

Strany 38

7Example vent systemNOTE: For external venting, flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly

Strany 39

8If connecting to a 3-wire system:Local codes may permit the use of a UL listed, 3-wire, 250-volt, 40- or 50-amp range power supply cord (pigtail). Th

Strany 40 - W10253462A

9INSTALLATION INSTRUCTIONSUnpack Range1. Remove shipping materials, tape and film from the range. Keep cardboard bottom under range.2. Remove oven rac